Calibration Explorer 0.2.0 reference workflow Silent step-by-step capture of the actual released interface. This is not a real-time recording. Captured on 4 October 2026 from the public version 0.2.0 using the UCI handwritten-digit reference. These are Codex-operated engineering observations, with zero independent human participants. The 80% threshold is illustrative, not optimised or recommended. 1. Load the reference Load the handwritten-digit reference. Policy validation is selected; the 1,797 test rows remain unopened. 2. Inspect a linked reliability bin Select original bin 15: 412 predictions, 98.3% mean confidence and 100% observed accuracy. 3. Fit on calibration rows Fit temperature using only 574 calibration rows. The fitted value is 0.72598. 4. Lock an illustrative threshold Lock an illustrative 80% threshold on policy validation before opening the test split. 5. Review the test comparison Review 1,797 test predictions. Accuracy stays at 94.9%; NLL changes from 0.1760 to 0.1575. 6. Preview and save the report Preview the test report. Source rows are excluded; the actual HTML download matches this preview.